1SKC000006C0201
1/85
Automation Technologies
Optocouplers
OBC 0100 - 24 V DC OBC 0100 - 48 V DC
BAMH 9,1 mm 50
BAMH V0 9,1 mm 50
BADH 12 mm 50
RLV
5 RC55
BAMH BADH
OBC 0100
OBC 0100 24 V DC
1 0.04
OBC 0100 48 V DC
1 0.04
A
B
C
D
29 1.14"
33 1.30"
62 2.44"
90
3.54"
97,5
3.84"
95 3.74"
OBC 0100 - 24 V DC
OBC 0100 - 48 V DC
RLV
5 mA
10.2 V DC 40.8 V DC
20 µs / 50 µs 20 µs / 50 µs
7000 Hz 7000 Hz
1 mA
100 mA
1 V
1.3 V
UL 94 V0
0.5-4 mm² / 20-12 AWG
0.5-2.5 mm² / 20-12 AWG
2.5 mm² / 12 AWG
7 mm .276"
3.5 .137"
IP 20 NEMA 1
0.4-0.6 Nm 3.5-5.3 lb.in
IN
IN
Description Type Order P/N
Packaging Weight
kg
Optocoupler module 24 V DC
Optocoupler module 48 V DC
Accessories
High end stop
Lengthwise marker
Marking method see markers
Order codes
Derating curve
Electronic
Interfaces
R900 optocoupler modules DIN 3
OBC 0100 - 2.5 mm² blocks - 9 mm .354" spacing
center of rail
Opto. characteristics
INPUT
Input voltage
Input current
Pull-in voltage at Is=100%
Switching time C / O
Operating frequency
Permissible leakage current
OUTPUT
Output voltage
Output current min.
Output current max.
Output leakage current at
Umax.
Residual voltage at I max and U
rated typical
max.
Frequency on inductive load
Isolation Input / Output
TEMPERATURE
Ambient temperature storage
operating
Other characteristics
Body material grey
Wire Solid wire
size Stranded wire
Rated wire size
Wire stripping length
Recommended screwdriver
Protection
Recommended torque
Approvals
10.2 V to 28.8 V DC 40.8 V to 57.6 V DC
7 mA to 12 V / 10 mA to 24 V
5 to 60 V DC
3000 V RMS
- 40°C to + 80°C
See derating curve
Characteristics
1SNA 114 836 R0000
1SNA 194 836 R0100
1SNA 116 900 R2700
1SNA 103 849 R0300
1SNA 608 017 R0600
1SNA 608 021 R0200