Vista de pagina 74
1SKC000006C0201
3/71
Automation Technologies
Optocouplers
...M 4/9.R111
M 4/9.R111 M 4/9.R111L
12 V 24 V 12 V 24 V
0.3 W 0.3 W 0.6 W 0.8 W
24 mA 14 mA 52 mA 33 mA
1.2 V DC 2.4 V DC 1.2 V 2.4 V
12 V / 150 V DC - 250 V AC
10 mA / 5 A
0.6 VA / 1250 VA
0.6 W / 150 W
1 x 10
6
2 x 10
7
5 ms
6 ms 7 ms
4 ms
UL 94 V0
0.2-4 mm² / 22-12 AWG
0.22-2.5 mm² / 22-12 AWG
2.5 mm² / 12 AWG
9 mm .354"
3.5 mm .137"
IP 20 NEMA 1
0.4-0.6 Nm 3.5-5.3 lb.in
M 4/9.R111 12 V DC 10 0.02
M 4/9.R111 24 V DC 10 0.02
M 4/9.R111L 12 V DC 10 0.02
M 4/9.R111L 24 V DC 10 0.02
11
A2
A1
14
M 4/9.R111...
1
2
5
7
4
6
3
M 4/9.R111
M 4/9.R111L
8
9
BAMH 9,1 mm 50
AL2 (1) 50
AL3 (1) 50
DCG 10
FC2 10
BJS9 (1)(2)
BJS9 (1)(2)
EV6D (1)(2) 20
AD2,5 50
PC9 10
11
Relay
Interfaces
R910 relay modules DIN 1-3
M 4/9.R111... - 2.5 mm² blocks - 9 mm .354" spacing
center of rail
Relay characteristics
COIL
Rated voltage +20%, -20% on DC
Power
Rated current
Drop-out voltage
Status device
CONTACT
Type
Voltage switching range min./max.
Current switching range
Load switching range
AC1 min. / max.
DC1 min. / max.
Number of on-load operations
Number of off-load operations
Pull-in time (delay time)
Drop-out time (delay time)
Bounce time
Insulation coil / contacts
Breakdown voltage with 1.2/50µ wave
Insulation contacts/contacts
Storage ambient temperature
Operating ambient temperature
Other characteristics
Body material grey
Wire Solid wire
size Stranded wire
Rated wire size
Wire stripping length
Recommended screwdriver
Protection
Recommended torque
Approvals
lamp
1 NO
3000 V RMS
4000 V RMS
750 V RMS
-40°C to +80°C
See derating curve hereunder
Characteristics
Description Type Order P/N
Packaging Weight
kg
Relay module 12 V DC
Relay module 24 V DC
Relay module with lamp 12 V DC
Relay module with lamp 24 V DC
Order codes
Accessories
Derating curve
(1) These accessories can be used on the lower connection only.
(2) Use of these accessories requires the user to cut out the precut partition.
1SNA 607 029 R0100
1SNA 607 030 R0600
1SNA 607 001 R0600
1SNA 607 002 R0700
1SNA 114 836 R0000
1SNA 163 070 R0000
1SNA 163 261 R0000
1SNA 163 218 R0500
1SNA 007 865 R2600
1SNA 177 583 R1200
1SNA 177 584 R1300
1SNA 168 400 R1600
1SNA 114 205 R2000
1SNA 210 160 R1200
1 High end stop (all rails)
2 Test socket DIA. 2 mm
DIA. 3 mm
3 Test device grey
4 Test plug
5 Jumper bar 8 poles
not assembled 16 poles
6 Sub-assembly for jumper bar
(screw + jumper + post)
7 IDC jumper
8 Comb type jumper bar
9 Marking method
RC65 and RC610
see markers
Vista de pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 94 95

Comentarios a estos manuales