Digital BUS-WATCH
®
HDx00
Page 67 of 85
Radio Engineering Industries, Inc.
640430 -- Rev 0 -- 1/12/2012
two preset vehicle type to choose from: School Bus and Transit. When set to custom,
each channel can have its own name and OSD abbreviation.
Vehicle Input Template: DVR gives two preset templates School Bus and Transit
and one Custom setting that allows user to configure the template manually. Use
remote and on-screen keyboard to enter information.
Figure 55: Input Setup - Custom
Input #: the input numbers correspond to pin number of the DVR input.
Description: name of the signal. Use remote to enter name.
Disp: OSD abbreviation. Use remote to enter abbreviation.
Input When Activate: set to High if signal is high (positive) when
activated; set to Low if signal is low (ground or negative) when activated.
Alarm When Activate: when set to On, DVR triggers an alarm when the
particular input is activated.